Miami-Dade · Broward · Palm Beach · Mon–Sat 8 AM–6 PM
Tell us what the fireplace is doing, which fuel it runs on and the brand. You get a call back within 2 business hours, Mon–Sat 8 AM–6 PM.

Gas fireplace repair
Gas fireplace repair in Miami starts with a short request: what the fireplace does, what fuel it runs on and the brand. The contractor calls back within 2 business hours with what the visit involves, and you get a price quote in writing before any repair begins. You pay after the work is done.
Most gas fireplace problems come from the parts that light and hold the flame. Florida conditions, a humid and salty climate, speed up wear on those parts, so a fireplace that sat unused all summer often gives trouble on the first cool evening. These are the signs that point to them:
A smell of gas is not a repair request, and it is not something to wait out. Leave the house, keep switches and flames away, and call 911 or your gas utility first, since a leak or smoke indoors is an emergency. When the smell is gone and the fireplace is cleared for use, send the request.
How it works
A few taps: what's wrong, where, and when you need it. Or call during business hours.
We confirm the problem, the service call price and your arrival window. Requests sent after 6 PM or on Sunday get a call the next business morning.
The same day for morning requests with an open slot, otherwise the next business day. You get a text when the technician is on the way.
You see a photo of the problem and an itemized estimate before the repair starts. You pay after the work is done.
Fireplace parts
A gas fireplace has a short chain of parts: an igniter makes the spark, a pilot holds a small flame, a sensor confirms the flame, a valve lets the gas through and a burner spreads it. When one link fails, the fireplace stops at that point, so the symptom usually tells which part to look at first. The table lists the common ones, so you can describe the problem clearly when you send the request.
| Part | What it does | What you notice when it fails |
|---|---|---|
| Pilot assembly | Holds a small flame that lights the burner | The pilot light will not light, or goes out on its own |
| Thermocouple or thermopile | Senses the pilot flame and tells the valve to stay open | The pilot lights while you hold the knob, then drops when you let go |
| Igniter or ignition module | Makes the spark on fireplaces without a standing pilot | Clicking with no flame, or no click at all |
| Gas valve | Opens and closes the gas supply to the burner | The pilot burns, but the main burner never starts or will not shut off |
| Burner and ports | Spread the gas into an even flame | Uneven or yellow flame, or soot on the logs and glass |
| Remote, wall switch and receiver | Send the on and off signal | The fireplace works at the valve but not from the remote |
| Glass front | Seals the firebox on direct vent models | Cracks, a heavy film or a gap at the gasket |
A clogged burner or a lazy yellow flame is usually visible, while a valve or a sensor needs a proper test to diagnose, so the part is named before anything is replaced. The quote is itemized line by line. You approve it first and pay after the work. Other heating work is on the heating and air in Miami page.
Who we help

Told your AC is done? Compare three turnkey packages from $6,900 and get a free second opinion before you sign anything.
See replacement packages
You don't have to be there. The tenant gets a text before arrival, you get photos and video before and after, and the invoice goes to the name and email you choose.
Send a rental request
Call or send a request before noon to be seen the same day when the schedule allows. The service call is $89 Mon–Fri and $0 with a same-visit repair.
Call now
A certificate of insurance naming your association before work starts, work inside the unit, and maintenance contracts with a technician on site within 4 business hours.
Commercial and condo serviceFuel and type
Two facts about your fireplace shape the repair: the fuel and the type. Some homes have a natural gas line, others use propane (LP), and the two fuels use different parts. A short note in your request saves a trip for the wrong part. If you are not sure, the data plate inside the firebox or near the valve shows the fuel and model; have it handy for the callback.
| Type | How it works | What to mention in the request |
|---|---|---|
| Direct vent | Sealed glass front, vents through a pipe to the outside | Brand, fuel, whether the glass is cracked or fogged |
| Vent-free | No chimney, burns inside the room | Brand, fuel, any smell or soot on walls |
| Gas logs in a masonry fireplace | Log set in a wood-burning firebox | Fuel, whether the logs are lit by a key or a switch |
| Insert | Gas unit fitted into an old fireplace | Brand and model from the plate |
| Outdoor fire pit or fire feature | Burner in a bowl or table, often on propane | Fuel, remote or push button, how the unit sits |
Salt and humidity are the Florida part of the story. Indoor or out, near the coast, in Miami Beach, Coral Gables or Fort Lauderdale, salt in the air corrodes small metal parts, and damp air leaves a film on the glass and burner. Tell us how long the fireplace has gone unused and whether it is near the water. The contractor confirms on the callback what can be done for your type and fuel, so you hear it before anyone drives out.
Service area
Based in Aventura, between Miami and Fort Lauderdale.

Miami, Miami Beach, Aventura, North Miami, Coral Gables, Doral, Hialeah, Kendall, Key Biscayne, Miami Gardens, Miami Lakes, Pinecrest, Palmetto Bay, Cutler Bay, Homestead
Fort Lauderdale, Hollywood, Hallandale Beach, Pembroke Pines, Miramar, Davie, Plantation, Sunrise, Weston, Cooper City, Coral Springs, Coconut Creek, Tamarac, Pompano Beach, Deerfield Beach
Boca Raton, Delray Beach, Boynton Beach, Lake Worth, West Palm Beach, Wellington, Royal Palm Beach, Palm Beach Gardens, Jupiter
FAQ
It depends on the part and the labor. A pilot assembly and a gas valve are very different jobs. The contractor writes the price down line by line before any repair starts, so you decide with the number in front of you. You pay after the work is done, not before. There is no fixed price, because it depends on the part.
A pilot light that will not stay lit. Usually the thermocouple or thermopile that senses the flame has worn out, or the pilot assembly is dirty. It tends to show up on the first cool evening after months of sitting idle.
Many modern units have a flame-failure safety device that cuts the gas, but older units and gas log sets may not. Do not keep relighting the pilot again and again. If it keeps going out, stop and send a request. If you smell gas, leave the house and call 911 or your gas utility before anything else.
Send a request here with the symptom, the fuel and the brand. The local contractor calls you back in business hours and tells you what the visit involves. A request after 6 PM or on Sunday is answered the next business morning.
Mention which one you have in the request, and the contractor confirms on the callback what can be done for your unit. The data plate shows the fuel and the model.
You can check that the wall switch is on, that the remote has fresh batteries, and that the gas valve to the fireplace is open. Then stop. Opening the valve compartment and working on gas parts is a job for a licensed contractor, so send the request.
The manual lists the schedule the manufacturer recommends. If you want a yearly check, mention it in the request, and the callback confirms what the visit covers.
Didn't find your answer?
Ask it on the call. It comes within two hours during business hours.
Request service
Send a request now and expect a call within two hours, Monday to Saturday. The service call is $0 when the repair is done on the same visit.